Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
                                            Some full text articles may not yet be available without a charge during the embargo (administrative interval).
                                        
                                        
                                        
                                            
                                                
                                             What is a DOI Number?
                                        
                                    
                                
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
- 
            Some thunderstorms in Cordoba, Argentina, present a charge structure with an enhanced low-level positive charge layer, and practically nonexistent upper-level positive charge. Storms with these characteristics are uncommon in the United States, even when considering regions with a high frequency of anomalous charge structure storms such as Colorado. In this study, we explored the microphysical and kinematic conditions inferred by radar that led to storms with this unique low-level anomalous charge structure in Argentina, and compared them to conditions conducive for anomalous and normal charge structures. As high liquid water contents in the mixed-phase layer lead to positive charging of graupel and anomalous storms through the non-inductive charging mechanism, we explored radar parameters hypothesized to be associated with large cloud supercooled liquid water contents in the mixed-phase layer and anomalous storms, such as mass and volume of hail and high-density graupel, large reflectivity associated with the growth of rimed precipitation to hail size, and parameters that are proxies for strong updrafts such as echo-top and Zdr column heights. We found that anomalous storms had higher values of mass and volume of hail in multiple sub-layers of the mixed-phase zone and higher frequency of high reflectivity values. Low-level anomalous events had higher hail mass in the lower portion of the mixed-phase zone when compared to normal events. Weaker updraft proxies were found for low-level anomalous events due to the shallow nature of these events while there was no distinction between the updraft proxies of normal and anomalous storms.more » « less
- 
            Abstract The electrical charge carried by raindrops provides significant information about thunderstorm electrification mechanisms, since the charge acquired by hydrometeors is closely related to the microphysical processes that they undergo within clouds. Investigation of charges on raindrops was conducted during the Remote sensing of Electrification, Lightning, And Meso‐scale/micro‐scale Processes with Adaptive Ground Observations field campaign. A newly designed instrument was used to determine simultaneously the fall velocity and charge for precipitating particles. Hydrometeor size and charge were measured in Córdoba city, Argentina, during electrified storms. Temporal series of size‐charge of single raindrops were recorded for two storms, which were also monitored with a Parsivel disdrometer and Lightning Mapping Array. The results show that the magnitude of the electric charges range between 1 and 50 pC and more than 90% of the charges are mainly carried by raindrops >1 mm, even though most of the raindrops are smaller than 1 mm. Furthermore, the measurement series show charged hydrometeors of both signs all the time. A correlation between the sizes and the charges carried by the raindrops was found in both storms.more » « less
- 
            Abstract During November 2018–April 2019, an 11-station very high frequency (VHF) Lightning Mapping Array (LMA) was deployed to Córdoba Province, Argentina. The purpose of the LMA was validation of the Geostationary Lightning Mapper (GLM), but the deployment was coordinated with two field campaigns. The LMA observed 2.9 million flashes (≥ five sources) during 163 days, and level-1 (VHF locations), level-2 (flashes classified), and level-3 (gridded products) datasets have been made public. The network’s performance allows scientifically useful analysis within 100 km when at least seven stations were active. Careful analysis beyond 100 km is also possible. The LMA dataset includes many examples of intense storms with extremely high flash rates (>1 s−1), electrical discharges in overshooting tops (OTs), as well as anomalously charged thunderstorms with low-altitude lightning. The modal flash altitude was 10 km, but many flashes occurred at very high altitude (15–20 km). There were also anomalous and stratiform flashes near 5–7 km in altitude. Most flashes were small (<50 km2 area). Comparisons with GLM on 14 and 20 December 2018 indicated that GLM most successfully detected larger flashes (i.e., more than 100 VHF sources), with detection efficiency (DE) up to 90%. However, GLM DE was reduced for flashes that were smaller or that occurred lower in the cloud (e.g., near 6-km altitude). GLM DE also was reduced during a period of OT electrical discharges. Overall, GLM DE was a strong function of thunderstorm evolution and the dominant characteristics of the lightning it produced.more » « less
- 
            Abstract In this study we explored the environmental conditions hypothesized to induce a dominant charge structure in thunderstorms in the province of Cordoba, Argentina, during the RELAMPAGO‐CACTI (Remote sensing of Electrification, Lightning, And Mesoscale/microscale Processes with Adaptive Ground Observations‐Clouds, Aerosols, Complex Terrain Interactions) field campaigns. Hypothesized environmental conditions are thought to be related to small warm cloud residence time and warm rain growth suppression, which lead to high cloud liquid water contents in the mixed‐phase zone, contributing to positive charging of graupel and anomalous charge structure storms. Data from radiosondes, a cloud condensation nuclei (CCN) ground‐based instrument and reanalysis were used to characterize the proximity inflow air of storms with anomalous and normal charge structures. Consistent with the initial hypothesis, anomalous storms had small warm cloud depth caused by dry low‐level humidity and low 0°C height. Anomalous storms were associated with lower CCN concentrations than normal storms, an opposite result to the initial expectation. High CAPE is not an important condition for the development of anomalous storms in Argentina, as no clear pattern could be found among the different parameters calculated for updraft proxy that would be consistent with the initial hypothesis.more » « less
- 
            Abstract A new automated method to retrieve charge layer polarity from flashes, named Chargepol, is presented in this paper. Using data from the NASA Lightning Mapping Array (LMA) deployed during the Remote sensing of Electrification, Lightning, And Mesoscale/microscale Processes with Adaptive Ground Observations (RELAMPAGO) field campaign in Cordoba, Argentina, from November 2018 to April 2019, this method estimates the polarity of vertical charge distributions and their altitudes and thicknesses (or vertical depth) using the very‐high frequency (VHF) source emissions detected by LMAs. When this method is applied to LMA data for extended periods of time, it is capable of inferring a storm's bulk electrical charge structure throughout its life cycle. This method reliably predicted the polarity of charge within which lightning flashes propagated and was validated in comparison to methods that require manual assignment of polarities via visual inspection of VHF lightning sources. Examples of normal and anomalous charge structures retrieved using Chargepol for storms in Central Argentina during RELAMPAGO are presented for the first time. Application of Chargepol to five months of LMA data in Central Argentina and several locations in the United States allowed for the characterization of the charge structure in these regions and for a reliable comparison using the same methodology. About 13.3% of Cordoba thunderstorms were defined by an anomalous charge structure, slightly higher than in Oklahoma (12.5%) and West Texas (11.1%), higher than Alabama (7.3%), and considerably lower than in Colorado (82.6%). Some of the Cordoba anomalous thunderstorms presented enhanced low‐level positive charge, a feature rarely if ever observed in Colorado thunderstorms.more » « less
- 
            Abstract Previous studies have shown that subsequent leaders in positive cloud‐to‐ground lightning (+CG) flashes rarely traverse pre‐existing channels to ground. In this paper, we present evidence that this actually can be common, at least for some thunderstorms. Observations of +CG flashes in a supercell storm in Argentina by Córdoba Argentina Marx Meter Array (CAMMA) are presented, in which 54 (64%) of 84 multiple‐stroke +CG flashes had subsequent leaders following a pre‐existing channel to ground. These subsequent positive leaders are found to behave similarly to their negative counterparts, including propagation speeds along pre‐existing channels with a median of 8 × 106 m/s, which is comparable to that of negative dart leaders. Two representative multiple‐stroke +CG flashes are presented and discussed in detail. The observations reported herein call for an update to the traditional explanation of the disparity between positive and negative lightning.more » « less
- 
            Abstract The Córdoba Argentina Marx Meter Array (CAMMA), consisting of 10 second‐generation Huntsville Alabama Marx Meter Array (HAMMA 2) sensors, operated at Córdoba, Argentina, during the Remote sensing of Electrification, Lightning, And Mesoscale/microscale Processes with Adaptive Ground Observations (RELAMPAGO) field campaign in late 2018. Initial results obtained from the campaign demonstrate that the new sensor is able to provide a significantly more detailed depiction of various lightning processes than its first generation. The lightning flashes mapped by the CAMMA and a colocated Lightning Mapping Array (LMA) were compared. The overall flash structures mapped by the CAMMA and the LMA look similar for most of the flashes. However, comparisons at smaller time scale show that the majority of CAMMA and LMA sources are not concurrent, indicating that unmatched sources were possibly due to different physical processes in leader propagation dominating different frequencies and differences in data processing and location techniques.more » « less
 An official website of the United States government
An official website of the United States government 
				
			 
					 
					
